9 February 2006
(HPWLI 10035-01A)
Waco Composites I, Ltd.
481-A Texas Central Parkway
P.O. Box 21223
Waco, Texas 76702-1223
Attention: David Breeland
Gentlemen:
In accordance with your instructions, H.P. White Laboratory, Inc. conducted forced entry resistance testing of one rigid fiberglass sample, identified as Model ArmorCore UL Level 3 (see enclosed data record for construction description), received 9 January 2006 via United Parcel Service.
Testing was conducted in accordance with your instructions, and the modified forced entry resistance provisions of ASTM F1233-98. Forced entry resistance testing was to begin with Sequence 1, and was to be terminated at body passage. Ballistic resistance testing was not conducted. Table I presents a summary of the enclosed data records.
| Class | Sequence | Description | Results |
| I | 01 | Ball Peen Hammer | 1. Abrading of surface fibers. |
| II | 02-07 | Ball Peen Hammer, Sledge Hammer & 1-1/2 inch Pipe, CO2 Extinguisher & Sledgehammer, Propane Torch & Ripping Bar | 1. Abrading of surface fibers. |
| III | 08-16 | 120 lb Ram, Sledgehammer & 4 inch Pipe, Sledgehammer, Propane Torch & Ripping Bar, Hammer & Chisel, Gasoline, Sledgehammer & Angle Iron, Sledgehammer | 1. 1.5 x 1 inch through-hole. 2. Contraband passage. (a) |
| IV | 17-27 | 120 lb Ram, Sledgehammer & 4 inch Pipe, Sledgehammer, Propane Torch & Wood Maul, Sledgehammer, Ripping Bar, Fire Axe, Hammer & Chisel, Acetone, Sledgehammer | 1. 2.5 x 1 inch through-hole. 2. 6 inch extended through slice. |
| V | 28-32 | 120 lb Ram, Sledgehammer & 4 inch Pipe, Sledgehammer, Propane Torch & Fire Axe | 1. 9 x 6 inch through-hole. 2. Body passage. (b) |
| (a) Pursuant to ASTM F1233-98, Paragraph 9.2.4.1. (b) Pursuant to ASTM F1233-98, Paragraph 9.2.4.2 |
|||
Waco Composites I, Ltd.
Attention: David Breeland
9 February 2006
(HPWLI 10035-01A)
Page 2
Based upon the data presented in Table I, the Model ArmorCore UL Level 3 fiberglass sample submitted for testing SATISFIED the contraband passage requirement of ASTM F1233-98, Class II, Paragraph 9.2.4.1.
Based upon the data presented in Table I, the Model ArmorCore UL Level 3 fiberglass sample submitted for testing SATISFIED the body passage requirement of ASTM F1233-98, Class IV, Paragraph 9.2.4.2.
This conclusion is based on data obtained from having tested only the sample submitted, and should NOT be interpreted as an endorsement by H.P. White Laboratory, Inc. of the continuing quality, or performance, of any other items of the same, or similar, design.
Please find photographs and videotape coverage (VHS format) of the testing enclosed herein.
In accordance with your instructions, the test sample is being returned via United Parcel Service. Should you have any questions regarding this matter, or if we may be of any further service, please do not hesitate to contact us.
Very Truly Yours,
H.P. WHITE LABORATORY, INC.
Craig B. Dunn
H.P. WHITE LABORATORY, INC.
Date: 8 February 2006
HPWLI Job: 10035-01
DATA RECORD
-Forced Entry Testing of Transparent Materials/Assemblies-
(ASTM F1233-98)(MODIFIED)
| Make, Model or Sample Number: | ArmorCore UL Level 3 |
| Sample Description: | Fiberglass cloth impregnated with thermoset polyester resin |
| Four corner thicknesses: 0.490 inch, 0.504 inch, 0.491 inch, 0.483 inch (Avg: 0.492 inch) | |
| Weight 32.1 lbs. | |
| Submitted By: | Waco Composites I, Ltd. |
| Test Sequence | Threat | Description | Procedure | Results | Ballistic | Pass/Fail | |
| Contra Entry | Body Entry | ||||||
| Ballistic | NA | NA | NA | NA | NA | NA | NA |
| 01 | Blunt | Ball Peen (16", 32 oz.) | 10 Impacts | 1. Abrading of surface fibers. | NA | Pass | Pass |
| Ballistic: | NA | ||||||
| F.E. Class I (Seq. 01): (Contra Entry) (Body Entry) |
Pass Pass |
||||||
| Test Sequence | Threat | Description | Procedure | Results | Pass/Fail | |
| Contra Entry | Body Entry | |||||
| 02 | Blunt | Ball Peen (16", 32 oz.) | 10 Impacts | 1. Abrading of surface fibers. | Pass | Pass |
| 03 | Sharp | Sledgehammer and 1-1/2" pipe | 25 Impacts | 1. Abrading of surface fibers. | Pass | Pass |
| 04-05 | Therm Blunt |
Fire Extinguisher, CO2 Sledgehammer (36", 12 lbs.) |
1 minute 25 impacts |
1. No apparent damage. | Pass | Pass |
| 06-07 | Therm Blunt |
Propane Torch (Gen'l. purpose tip) Ripping bar (24" claw/chisel ends) |
5 minutes 10 impacts |
1. No apparent damage. | Pass | Pass |
| F.E. Class II (Seq. 02-07): (Contra Entry) (Body Entry) |
Pass Pass |
|||||
| Test Sequence | Threat | Description | Procedure | Results | Pass/Fail | |
| Contra Entry | Body Entry | |||||
| 08 | Blunt | 120-pound Ram (2 man) | 10 Impacts | 1. No apparent damage. | Pass | Pass |
| 09 | Blunt | Sledgehammer & 4" Pipe (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | Pass | Pass |
| 10 | Blunt | Sledgehammer (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | Pass | Pass |
| 11-12 | Therm. Sharp |
Propane Torch (Gen'l. purpose tip) Ripping bar (24" claw/chisel ends) |
5 minutes 10 impacts |
1. ¼ x ¼ inch through-hole. 2. Contraband Passage. (a) |
FAIL | Pass |
| 13 | Sharp | Hammer & Chisel (16 oz.) | 25 Impacts | 1. Abrading of surface fibers. | NA | Pass |
| 14 | Chem. | Gasoline | ½ pint (Chemical NOT therm.) | 1. No apparent damage. | NA | Pass |
| 15 | Sharp | Sledgehammer and Angle Iron (12 lbs., 2" x 2" x ¼") | 25 impacts | 1. 1-1/2 x 1 inch through-hole. | NA | Pass |
| 16 | Blunt | Sledgehammer (36", 12 lbs.) | 25 impacts | 1. No apparent damage. | NA | Pass |
| F.E. Class III (Seq. 08-16): (Contra Entry) (Body Entry) |
FAIL Pass |
|||||
| Remarks: (a) Pursuant to Paragraph 9.2.4.1. | ||||||
| Test Sequence | Threat | Description | Procedure | Results | Pass/Fail | |
| Contra Entry | Body Entry | |||||
| 17 | Blunt | 120-pound Ram (2 man) | 10 Impacts | 1. No apparent damage. | NA | Pass |
| 18 | Blunt | Sledgehammer & 4" Pipe (36", 12 lbs.) | 25 Impacts | 1. Abrading of surface fibers. | NA | Pass |
| 19 | Blunt | Sledgehammer (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | NA | Pass |
| 20-21 | Therm. Sharp |
Propane (Gen'l. purpose tip) Wood maul (36", 8 lbs.) |
5 minutes 25 Impacts |
1. 2-1/2 x 1 inch through-hole. | NA | Pass |
| 22 | Blunt | Sledgehammer (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | NA | Pass |
| 23 | Sharp | Ripping bar (24", claw/chisel ends) | 10 Impacts | 1. No apparent damage. | NA | Pass |
| 24 | Sharp | Fire axe (36", 6 lbs., axe/pick head) | 25 Impacts | 1. 6 inch extended through-slice. | NA | Pass |
| 25 | Sharp | Hammer/Chisel (16 oz.) | 25 Impacts | 1. Abrading of surface fibers. | NA | Pass |
| 26 | Chem. | Acetone | ½ pint | 1. No apparent damage. | NA | Pass |
| 27 | Blunt | Sledgehammer (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | NA | Pass |
| F.E. Class IV (Seq. 17-27): (Contra Entry) (Body Entry) |
NA Pass |
|||||
| Test Sequence | Threat | Description | Procedure | Results | Pass/Fail | |
| Contra Entry | Body Entry | |||||
| 28 | Blunt | 120-pound Ram (2 man) | 10 Impacts | 1. No apparent damage. | NA | Pass |
| 29 | Blunt | Sledgehammer & 4" Pipe (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | NA | Pass |
| 30 | Blunt | Sledgehammer (36", 12 lbs.) | 25 Impacts | 1. No apparent damage. | NA | Pass |
| 31-32 | Chem. Sharp |
Propane Torch (Gen'l. purpose tip) Fire axe (36", 6 lbs., axe/pick head) |
5 minutes 25 Impacts |
1. Two 5 inch extended slices. 2. 9 x 6 inch through-hole. 3. Body Passage. (a) |
NA | FAIL |
| F.E. Class V (Seq. 28-32): (Contra Entry) (Body Entry) |
NA FAIL |
|||||
| Remarks: (a) Pursuant to Paragraph 9.2.4.2. | ||||||